ELECTRO CHEMICAL INSTRUMENTS
Contech, the pioneers in Laboratory Balances has added
high quality laboratory equipments like pH Meters,
Conductivity Meters, DO Meters, Polarimeters,
Refractometers, Melting Point Apparatus to the existing
range. Vast experience and in depth knowledge of
Laboratory needs and instrumentation has helped Contech
to roll out these most advanced technological products.
|
|
|

|
|
|
pH Meters |
|
|
Features
 |
Advanced Microcontroller based design.
|
 |
Display
of pH, mv, temp on backlite LCD. |
 |
RS-232
Interface ( Optional ). |
 |
Inbuilt
RTC ( Optional ). |
 |
GLP
compliant ( Optional ) . |
 |
Entry
of buffer value, machine ID through keyboard for
the GLP print out. |
 |
3 point
Automatic pH Calibration with buffer standards
4.0, 7.0 & 9.2 pH |
 |
3 point
manual pH calibration using with known buffer
standards. |
 |
Automatic temperature compensation ( Optional ). |
 |
Entry
of temperature through keyboard in the absence
of temperature sensor |
 |
Storage
upto 50 test results |
 |
Display
of time based pH sampling data upto 200 samples.
|
|
|
|
|
|
Model |
CpH-102 |
CpH-103 |
|
pH Range |
0-14pH |
0-14pH |
|
pH Resolution |
0.01pH |
0.001pH |
|
pH Accuracy |
+0.02pH |
+0.002pH |
|
Temperature compensation |
0-100 deg C |
0-100 deg C |
|
mV |
+2000mV |
+2000mV |
|
mV Resolution |
1mV |
0.1mV |
|
mV Accuracy |
+2mV |
+0.2mV |
|
|
Supply Voltage: 90-250V, 50 Hz
Operating temperature: 10-45 deg C
Humidity: 5-80% Rh
Automatic pH calibration: 3 points 4.0, 7.0 & 9.2pH
Manual pH calibration : 3 points using known
buffers.
Display: Backlite LCD
pH sensor: Glass pH electrod
|
|
|
|
|
|
|
|
|
|
|

|
|
|
Conductivity Meters |
|
Features
 |
Incorporates advanced automatic frequency
convertible and voltage technology to enhance
electrode's measuring capability and maintains
the electrode constant in standard solution of
different concentration. |
 |
One point calibration for the entire range.
|
 |
Advanced Microcontroller based design. |
 |
Display of Conductivity & temp on backlite LCD.
|
 |
RS-232 Interface (Optional). |
 |
lnbuilt RTC (Optional). |
 |
GLP compliant (Optional). |
 |
Entry of Conductivity electrode constant,
machine 10 through keyboard for the
GLP print out. |
 |
Automatic temperature compensation (Optional). |
 |
Entry of temperature through keyboard in the
absence of temperature sensor |
 |
Storage upto 50 test results |
|
|
|
|
Model |
CC-01 |
|
Conductivity Range |
0-200mS/cm |
|
Precision |
+1.0% full scale |
|
Resistivity |
0
to 50 M Ohm.cm |
|
Temperature |
-10.0 to 110.0oC |
|
TDS |
0
to 80g/L |
SpecificationsPower
Req : 90-250V, 50/60Hz, 10 Watt
Operating Temperature : 10 to 45 deg C
Humidity : 5-80% Rh
|
|
|
|
|
|
|
|
|
|